Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Fujitsu SPARC M12-2S : Reference


Reference Synopsis Last Modified Date
2264013.1 M12-upset_domain.keep-alive - Solaris panics but the reason is unknown to XSCF software 2017-10-17
2246209.1 M12-i2c.device_pcibox_fanbp - I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box 2017-10-17
2246199.1 M12-rci - An error was detected by an RCI-supported device connected via LAN 2017-10-17
2246181.1 M12-madm.ups.se - MADM software running on the domain has detected a serious UPS problem 2017-10-17
2245355.1 M12-upset_domain.obp - OBP in a domain may not be running correctly 2017-10-17
2245207.1 M12-upset_xscfu - A hard-to-diagnose failure of the XSCF occurred 2018-05-17
2245186.1 M12-mbc.se-dma - Error detected by the XSCF on the DMA interface of an MBC chip 2017-10-17
2244775.1 M12-jtag.device - JTAG write failure to a specific chip 2017-10-16
2244733.1 M12-if.fe-asic-stick - Fatal clock distribution error 2017-10-16
2244724.1 M12-xb.test_xbu_xb - Self-test error detected by an XB chip within itself or while trying to establish communication with another XB chip 2017-05-26
2244714.1 M12-xb.test_cmu_cpu - Self-test error detected by an XB chip within itself or while trying to establish communication with a CPU chip 2017-05-26
2243894.1 M12-cpu.core.strand.se - Fault Due to Serious Error on CPU 2017-08-10
2243875.1 M12-upset_config.bbid - On powerup a Building Block ID does not match the connected BB control cable 2017-05-23
2243874.1 M12-config.xbbox - A fault occurred during powerup 2017-05-23
2243546.1 M12-power.undervoltage_pcibox_iob - Undervoltage failure on an IOB in PCI Expansion Box. 2017-08-14
2243537.1 M12-power.warning_pcibox_psu - Undervoltage Warning or Overvoltage Warning on a Power Supply in PCI Expansion Box 2017-08-14
2243535.1 M12-power.warning_pcibox_iob - Undervoltage Warning or Overvoltage Warning on an IOB in PCI Expansion Box 2017-08-14
2243522.1 M12-device.misconfig_xbucable - An Invalid XBU Cable has been Detected 2017-05-17
2243520.1 M12-device.misconfig_xscfif - An Invalid Xscfif has been Detected 2017-05-17
2243519.1 M12-device.misconfig_xbbp - An Invalid XBBP has been Detected 2017-05-17
2243516.1 M12-device.misconfig_xbu - An Invalid XBU has been Detected 2017-05-17
2243514.1 M12-device.misconfig_cmu - An Invalid CMU has been Detected 2017-08-14
2243513.1 M12-asic.power.fail - A Power Failure has been Detected 2017-08-14
2243499.1 M12-device.misconfig_xbux - An Invalid Xbux has been Detected 2017-05-17
2243498.1 M12-device.misconfig_psubp - An Invalid Psubp has been Detected 2017-08-14
2243496.1 M12-upset.io.boot - Failure to boot Solaris on a domain 2017-08-14
2243429.1 M12-ioc.ch.leaf.se-no-credit-pci - Internal error detected by an IOC in a CPU chip 2017-08-14
2243024.1 M12-memory.se - DIMM Serious Error Detected 2017-08-21
2242784.1 M12-cpu.core.strand.ce-quiet - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip 2017-08-14
2241473.1 M12-cpu.core.strand.se-quiet - Too many CPU serious faults, such as 15012700, have occurred 2017-08-10
2241115.1 How to deal/recover from a hung/unresponsive Physical Partition (PPAR) or Guest Domain 2017-10-11
2240963.1 M12-if.fe-cpu-xb Fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ 2017-05-23
2219071.1 M12-device.fan.toofast - Rotation speed of a fan has risen above the threshold. 2017-09-12
2219070.1 M12-Testalert - A test fault and associated SNMP trap have been generated on an M12 server or XB-Box 2017-10-17
2219067.1 M12-device.fan.tooslow_pcibox - The rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) is incorrect 2017-08-23
2219066.1 M12-Heartbeat - A heartbeat SNMP trap has been generated on an M12 server or XB-Box 2017-06-29
2219064.1 M12-upset_config.xbu - A fault occurred during powerup 2017-05-23
2219063.1 M12-upset_config.opnl - Operator Panel (OPNL) not detected during powerup 2017-09-12
2219061.1 M12-upset_config.xbbox - A problem occurred during powerup 2017-05-23
2219060.1 M12-mbc.ce - Persistent correctable errors detected by an MBC chip within itself 2017-10-17
2219059.1 M12-madm.io.se - MADM software running on the domain has detected a serious IO problem 2017-10-17
2219058.1 M12-i2c.device_pcibox_linkbrd - I2C access failure to I2C devices on an link board in a PCI expansion box 2017-10-17
2219056.1 M12-io.pciex.pcibox.fe - Fatal error detected on a linkcard in a PCI slot or a linkbrd in a PCI expansion box 2017-10-17
2219054.1 M12-io.pciex.pcibox.se_linkcable - Error detected on a link cable connecting a link card and a PCI expansion box 2017-10-17
2219053.1 M12-domain.fe-unexpected-trap - An unexpected trap with unknown cause was detected by a CPU chip on a PPAR 2017-10-17
2219052.1 M12-i2c.device_pcibox_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) 2017-10-17
2219051.1 M12-i2c.device_linkcard - I2C access failure to I2C devices on the link card 2017-10-17
2219049.1 M12-io.pciex.pcibox.se_iob - Error detected on an IOB in a PCI expansion box 2017-10-17
2219048.1 M12-upset_domain.post - POST may not be running correctly in a domain 2017-10-17
2219047.1 M12-upset_ppar.config - PPAR(s) cannot be configured successfully 2017-10-17
2219046.1 M12-io.pciex.pcibox.fe_slot - Fatal error detected on a PCI Express slot in a PCI expansion box 2017-10-17
2219045.1 M12-xscfu - A hardware problem has been detected with an XSCFU or PSUBP 2017-10-17
2219043.1 M12-i2c.device_pcibox_iob - I2C access failure to I2C devices on an IOB in a PCI expansion box 2017-10-17
2219042.1 M12-defect_software - XCP software is diagnosed as faulty 2017-10-17
2219041.1 M12-io.pciex.pcibox.fe_iob - Fatal error detected on a IOB in a PCI expansion box 2017-10-17
2219039.1 M12-device.missing_pcibox_linkbrd_linkcable - PCI expansion box link cable not connected 2017-10-17
2219037.1 M12-upset_config.linkcable_pcibox_linkbrd_linkcable - An upset occurred during powerup 2017-10-17
2219036.1 M12-upset_pcibox.firmware - A hard-to-diagnose failure of the PCI expansion box occurred 2017-10-17
2219035.1 M12-upset_config.psu_pcibox - Insufficient operable PCI expansion box PSUs detected 2017-10-17
2219034.1 M12-upset_config.fan_pcibox - The number of fans in a PCI expansion box are insufficient 2017-10-17
2219033.1 M12-i2c.device_pcibox_linkbrd_linkcable - I2C access failure to I2C devices on a link cable when starting a PCI expansion box 2017-10-17
2219032.1 M12-i2c.device.seeprom-corrupt_pcibox - Invalid data checksums in a FRU SEEPROM in a PCI expansion box 2017-10-17
2219019.1 M12-io.pciex.linkcard.flash - Problem detected writing to flash memory on a link card 2017-10-17
2219018.1 M12-madm.io.fe - MADM software running on the domain has detected an IO problem 2017-10-17
2219017.1 M12-upset_domain.panic - Solaris panics but the reason is unknown to XSCF software 2017-10-17
2219016.1 M12-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box 2017-10-17
2219015.1 M12-i2c.device_opnl - I2C access failure to I2C devices on the Operator Panel (OPNL) 2017-10-17
2218993.1 M12-i2c.device-internal - Data compare error on I2C access to a specific chip 2017-10-17
2218992.1 M12-i2c.device_cmu - I2C write failure to a specific chip 2017-10-16
2218991.1 M12-if.se-mbc-xscf - Error detected on the interface between an MBC chip and the XSCFU or XSCF function on MBU or CMUL 2017-10-17
2218990.1 M12-mbc.se - Error detected by an MBC chip within itself 2017-10-17
2218988.1 M12-i2c.device.seeprom-corrupt - XSCF firmware found invalid SEEPROM checksums 2017-10-17
2218987.1 M12-i2c.device_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) 2017-10-17
2218986.1 M12-mbc.se-cmd - XSCF software-detected problem on the command interface between the XSCF and a MBC chip 2017-10-17
2218985.1 M12-mbc.fe - Fatal internal error detected by an MBC chip within itself 2017-10-17
2218984.1 M12-i2c.device - I2C access failure to I2C devices 2017-10-17
2218983.1 M12-if.ce-xb-xbucable - Permanent correctable errors detected at a cable connecting two XB chips 2017-05-26
2218982.1 M12-xb.ce - Persistent correctable errors detected in the logic internal to an XB chip 2017-05-26
2218981.1 M12-if.fe-asic-clk_xbu_xb - Fatal clock distribution error detected by a XB chip 2017-05-26
2218980.1 M12-if.ce-xb-cpu - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ 2017-05-26
2218826.1 M12-if.ce-xb-xb - Permanent correctable errors on the interface between two XB chips 2017-05-26
2218825.1 M12-if.ce-cpu-mbc - Permanent correctable errors on the interface between a CPU chip on a CMU or MBU and an MBC chip 2017-10-16
2218824.1 M12-xb.fe - Fatal internal error detected by an XB chip within itself 2017-05-23
2218823.1 M12-if.fe-xb-xbucable - Fatal error detected at cable connecting two XB chips 2017-05-23
2218822.1 M12-if.ce-cpu-xb - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ 2017-05-26
2218821.1 M12-if.ce-cpu-cpu - Persistent correctable errors on the interface between two CPU chips 2018-05-29
2218820.1 M12-if.fe-xb-xb - Fatal error on the interface between two XB chips 2017-05-23
2218811.1 M12-if.fe-cpu-cpu - Fatal error on the interface between CPU chips. 2017-05-23
2218810.1 M12-env.temp.over-fatal - An overtemperature condition is detected at a temperature sensor 2017-05-23
2218809.1 M12-if.fe-xb-cpu - Fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ 2017-05-23
2218808.1 M12-upset_config.fan - The number of fans are insufficient to permit powerup 2017-10-16
2218807.1 M12-if.fe-cpu-mbc - Fatal error on the interface between a CPU chip and MBC chip. 2017-10-16
2218803.1 M12-device.fan.toofast_pcibox - Rotation speed of a PCI Expansion box fan has risen above the threshold. 2017-09-12
2218802.1 M12-device.fail_pcibox_psu - A PSU signaled that it has failed 2017-09-11
2218801.1 M12-device.inserted - the presence of a FRU is unexpectedly detected 2017-09-12
2218789.1 M12-device.fail_psu - A PSU signaled that it has failed 2017-08-23
2218788.1 M12-env.power.loss - A power supply (PSU) detected a loss of AC power 2017-09-12
2218787.1 M12-env.temp.over - An overtemperature condition is detected by a temperature sensor 2017-09-12
2218786.1 M12-device_misconfig_ddc - An incorrect DDC was detected 2017-09-12
2218785.1 M12-device.fan.tooslow - The rotation speed of a fan (including fans in fan trays or in PSUs) is incorrect 2017-09-12
2218784.1 M12-env.temp.under - An undertemperature condition is detected by the inlet temperature sensor 2017-09-12
2218783.1 M12-device.missing_psu - Unable to start up system because not enough functional PSUs are available 2017-08-23
2218782.1 M12-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box 2017-09-12
2218779.1 M12-vllc.test - Fail-safe-protection circuit fault on start up of PPAR 2017-05-23
2218778.1 M12-env.temp.over-fail - Overtemperature fault 2017-10-16
2218777.1 M12-env.temp.over-warn - An overtemperature warning condition is detected by a temperature sensor 2017-10-16
2218776.1 M12-device.misconfig_psu - An incorrect PSU was detected in a box 2017-09-12
2218774.1 M12-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed 2017-09-11
2218773.1 M12-device.removed - the presence of a FRU detect signal suddenly disappears 2017-09-12
2218766.1 M12-upset_config.power - An upset occurred during powerup 2017-09-12
2218763.1 M12-device.missing_xbu_ddc - A DDC on an XBUQ in M12-2S or an XBUX in XB-Box is missing or could not be detected 2017-05-23
2218725.1 M12-device.fail_ddc - A DDC on a FRU signaled that it has failed 2017-09-11
2218724.1 M12-ioc.ch.ce - correctable errors detected by the IOC 2017-08-14
2218718.1 M12-device.pump.tooslow_vllc - Rotation speed of a Vapour and Liquid Loop Cooling (VLLC) pump is either lower than its predefined threshold or has stopped completely 2017-05-23
2218717.1 M12-power.power-off_pcibox_psu - XSCF failed to turn off the power to a PSU in a PCI expansion Box 2017-08-14
2218716.1 M12-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB 2017-08-14
2218715.1 M12-power.power-off - A fault occurred when the XSCF tried to turn off power to a DDC 2017-08-23
2218484.1 M12-power.warning_psu - Undervoltage warning or overvoltage warning detected on a PSU 2017-08-14
2218483.1 M12-power.warning - Undervoltage warning or overvoltage warning 2017-08-14
2218480.1 M12-power.overvoltage_pcibox_iob - Overvoltage failure detected on an IOB in PCI expansion Box 2017-08-14
2218462.1 M12-power.undervoltage - Undervoltage failure 2017-08-17
2218459.1 M12-io.pciex.switch.se - An error was detected within a PCIe switch 2017-08-14
2218458.1 M12-io.domain.fma - FMA running on a domain detects a PCI Express-related failure, and forwards information to XSCF 2017-08-14
2218457.1 M12-power.overvoltage - Overvoltage failure 2017-08-23
2218456.1 M12-io.pcie.device.se - An error was detected on a PCIe switch, onboard device, or a card in a PCI slot 2017-08-14
2218453.1 M12-ioc.ch.se - Internal error detected by an IOC in a CPU chip 2017-08-14
2218450.1 M12-io.pciex.switch.fe - Fatal error within a PCIe switch chip 2017-08-14
2218446.1 M12-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated 2017-08-14
2218444.1 M12-memory.mirror.fe.addr - Fatal error in a DIMM 2017-08-14
2218442.1 M12-cpu.chip.se - Uncorrectable error detected by a SPARC64 XII CPU chip 2017-08-21
2218417.1 M12-mac.bank.fe - Fatal error detected by the MAC chip within itself 2017-08-14
2218415.1 M12-mac.fe - Fatal error detected by the MAC within itself 2017-08-14
2218413.1 M12-mac.se - A serious error was detected by the MAC sub-chip within itself 2017-08-14
2218411.1 M12-mac.ce - Persistent correctable errors (CEs) detected by the MAC sub-chip within itself 2017-08-14
2218407.1 M12-io.pcie.device.fe - Fatal error detected on a card in a PCI slot or an onboard device 2017-08-14
2218406.1 M12-ioc.fe - Fatal error within an IOC detected by an IOC within itself 2017-08-21
2218404.1 M12-ioc.ch.fe - Fatal error within an IOC which is related to an IO Channel 2017-08-14
2218400.1 M12-memory.block.ue - DIMM uncorrectable error detected 2017-08-14
2218399.1 M12-cpu.ce - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip 2017-08-21
2218398.1 M12-cpu.core.ce - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip 2017-08-10
2218396.1 M12-memory.fe - Fatal error in a DIMM 2017-08-01
2218389.1 M12-memory.bank.err - DIMM errors detected by Power On Self Test (POST) 2017-08-21
2218388.1 M12-cpu.way.ce - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip 2017-08-14
2218387.1 M12-memory.block.mirror.ue - A data compare error has been detected when memory is in mirror mode 2017-08-14
2218386.1 M12-memory.block.pce - The number of DIMM permanent correctable errors (PCEs) exceeds threshold 2017-08-14
2218330.1 M12-cpu.core.strand.fe - Internal fatal error within a strand on a SPARC64 XII CPU 2017-08-10
2218319.1 M12-cpu.se-uncertain - Uncorrectable error detected by a SPARC64 XII CPU chip 2017-08-10
2218298.1 M12-cpu.se - Uncorrectable error detected by a SPARC64 XII CPU chip 2017-08-21
2218290.1 M12-cpu.se-offlinereq - Too many CPU faults, such as 05012100, have occurred 2017-08-21
2218276.1 M12-cpu.core.fe - Internal fatal error within a core on a SPARC64 XII CPU chip 2017-08-07
2218269.1 M12-cpu.fe - Internal fatal error within a SPARC64 XII CPU chip core 2017-08-07
1523796.1 SCF-8008-V0 - Correctable errors on the interface between XB chip and CPU chip exceed an acceptable threshold. 2017-03-23
1523795.1 SCF-8008-UT - Correctable errors on the interface between two CPU chips exceed an acceptable threshold 2017-03-23
1523787.1 SCF-8008-Q1 - The number of permanent correctable errors (PCEs) on single DIMM exceeds an acceptable threshold 2017-03-23
1523786.1 SCF-8008-PW - The number of intermittent correctable memory errors (ICEs) has exceeded an acceptable threshold 2017-03-23
1523771.1 SCF-8008-WV - A non-fatal uncorrectable error was detected within a MBC chip 2017-03-23
1523770.1 SCF-8008-T6 - Correctable errors on the interface between two XB chips exceed an acceptable threshold 2017-03-23
1523769.1 SCF-8008-SN - A data compare error has been detected within a CPU MAC when memory is in mirror mode 2017-03-23
1523767.1 SCF-8008-R9 - The number of intermittent correctable errors (ICEs) on single DIMM exceeds an acceptable threshold 2017-03-23
1523747.1 SCF-8008-NF - A permanent correctable memory error (PCE) has been detected 2017-03-23
1523673.1 SCF-8008-MK - An uncorrectable memory error (UE) has been detected 2017-03-23
1523672.1 SCF-8008-L8 - A non-fatal uncorrectable error has been detected on a strand on a CPU chip 2017-03-23
1523671.1 SCF-8008-KM - The number of correctable errors on a strand on a CPU chip has exceeded an acceptable threshold 2017-03-23
1523646.1 SCF-8008-J7 - The number of correctable errors within a way of a CPU chip's cache has exceeded an acceptable threshold. 2017-03-23