Asset ID: |
1-79-2219016.1 |
Update Date: | 2017-10-17 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2219016.1
:
M12-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
- Fujitsu M10 PCI Expansion Unit
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-io.pciex.pcibox.se
Fujitsu fault codes:
11000041, 11000062, 11000068, 11000069, 1100006a
Details
Type
- Hardware Fault
- io.pciex.pcibox.se
Severity
- Major
Description
-
Fault due to serious internal error detected by a link card or link board in a PCI expansion box.
The fault affects the PCI express fabric. The domain will face performance deterioration. The detected fault is listed in the following
categories:
- se-linkcard-lane-degraded: 11000041 The link card detects the PCIe lane has been degraded and is operating at reduced speed;
- se-linkcard-lane-degraded: 11000062 The link board detects the PCIe lane has been degraded and is operating at reduced bandwidth.
- se-link-lane-degraded: 11000068, 11000069, 1100006a The PCIe lane has been degraded between link card and link board and they are operating at reduce bandwidth.
Automated Response
- No immediate action is taken.
Impact
- Nothing is deconfigured.
Indicted Hardware
- First suspect is the link card, second suspect is a link cable between the link card and the PCI expansion box and the third suspect is the link board on PCI expansion box.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment