M12-if.fe-xb-cpu - Fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-if.fe-xb-cpu
Fujitsu fault codes:
01920403, 01920404, 01920463, 15021000, 15021001, 15021002,
15021003, 15061000, 15061001, 15061002, 15061003, 15061004,
15061005, 15061100, 15061101, 15061102, 15061103, 15062000,
15062001, 15062002, 15062003
Details
Type
- Hardware Fault
- if.fe-xb-cpu
Severity
- Major
Description
-
Fault due to a fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ.
Automated Response
- The single PPAR using this building block is reset.
Impact
- An XB-way is deconfigured on this PPAR.
Indicted Hardware
- The XBUQ is the first suspect and CMUU or CMUL is the second suspect.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)