Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2246199.1
Update Date:2017-10-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2246199.1 :   M12-rci - An error was detected by an RCI-supported device connected via LAN  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message IDs: M12-rci

Fujitsu fault code:

07F70001

Details

Type

Hardware Fault
   rci

Severity

Minor

Description

Fault due to an error that was detected by an RCI supported device connected via LAN.

The types of faults that are detected are:

- an RCI device is not responding and may be faulty;

- an RCI device reported an error.

Automated Response

If the RCI device is not responding, the system will continue to run, but there will be no communication with this RCI device.

If the RCI device reported an error, the information is logged, and no further action is taken.

Impact

Nothing is deconfigured.

Indicted Hardware

No FRU is specified. The error message contains the identity of RCI device.

Suggested Action for System Administrator

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback