Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218808.1
Update Date:2017-10-16
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218808.1 :   M12-upset_config.fan - The number of fans are insufficient to permit powerup  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-upset_config.fan

Fujitsu fault codes:

018AF030, 018AF031, 018AF0F1

Details

Type

Hardware Fault
   upset_config.fan

Severity

Major

Description

An upset occurred during powerup (either at connecting power cords to the system or initial powerup of PPARs) where the number of fans are insufficient.

Automated Response

For M12-1 or M12-2 systems, the platform will not be powered up.

For M12-2S systems, the building block will not be powered up.

Impact

Nothing is deconfigured.

Indicted Hardware

The fan is specified as a suspect.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.