Asset ID: |
1-79-2218980.1 |
Update Date: | 2017-05-26 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218980.1
:
M12-if.ce-xb-cpu - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-if.ce-xb-cpu
Fujitsu fault codes:
15060000, 15060001, 15060002, 15060003, 15060005, 15060100,
15060101, 15060102, 15060103, 15060104, 15060105, 15060106,
15060107, 15060200, 15060201, 15060202, 15060203
Details
Type
- Hardware Fault
- if.ce-xb-cpu
Severity
- Major
Description
-
Fault due to a permanent correctable error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ.
When the number of correctable error exceeds a predetermined threshold the lane is degraded and operates at a reduced bandwidth.
Automated Response
- No immediate action will be taken.
Impact
- A CPU is deconfigured.
Indicted Hardware
- The XBUQ is the first suspect and CMUU or CMUL is the second suspect.
For M12-2/M12-2S system with 2 CPU chip in a box, configuration of PCIe fabric will be changed triggered by CPU chip deconfiguration. This is taken place when ioreconfigure is set to true by setpparmode command.
Configuration of the PCIe fabric is changed to maintain access to all the onboard devices and PCIe slots even when either CMUU or CMUL is deconfigured.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment