Provide additional information for message ID: M12-io.pciex.pcibox.se_iob
Fujitsu fault code:
1100005C
Details
Type
- Hardware Fault
- io.pciex.pcibox.se_iob
Severity
- Major
Description
-
Fault due to a serious error detected by a microprocessor on an IOB in a PCI expansion box.
Automated Response
- No immediate action is taken.
Impact
- Nothing is deconfigured. The IOB is marked to be deconfigured. When a domain requests to re-start the PCI expansion box, this PCI expansion box will not start.
Indicted Hardware
- IOB is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.