Asset ID: |
1-79-1523671.1 |
Update Date: | 2017-03-23 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1523671.1
:
SCF-8008-KM - The number of correctable errors on a strand on a CPU chip has exceeded an acceptable threshold
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: SCF-8008-KM
Details
Type
- Hardware Fault
- fault.chassis.Athena-Server.cpu.SPARC64-X.strand.ce
Severity
- Minor
Description
-
The number of correctable errors on a strand on a CPU chip has exceeded an acceptable threshold. This fault occurs when the number of offline attempts has exceeded an acceptable threshold.
Automated Response
- The domain software will attempt to offline the strand on the CPU chip. The strand of the CPU chip will be deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
Impact
-
The performance of the system may be impacted as a result of removing the strand from operation.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.