Solution Type  Predictive Self-Healing Sure

Solution  1523672.1 :   SCF-8008-L8 - A non-fatal uncorrectable error has been detected on a strand on a CPU chip  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: SCF-8008-L8

Details

Type

Hardware Fault
   fault.chassis.Athena-Server.cpu.SPARC64-X.strand.se

Severity

Major

Description

A non-fatal uncorrectable error has been detected on a strand on a CPU chip.

Automated Response

The strand on the CPU chip is deconfigured.
Please notify mike.cootware@oracle.com when this issue is detected.

Impact

The non-fatal uncorrectable error trap may cause the domain to panic.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)