M12-if.ce-cpu-xb - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-if.ce-cpu-xb
Fujitsu fault codes:
15025100, 15025101, 15025102, 15025103, 15025200, 15025201,
15025202, 15025203
Details
Type
- Hardware Fault
- if.ce-cpu-xb
Severity
- Major
Description
-
Fault due to a permanent correctable error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ, detected by a CPU.
When the number of correctable error exceeds a predetermined threshold the lane is degraded and operates at a reduced bandwidth.
Automated Response
- No immediate action will be taken.
Impact
- A CPU is deconfigured.
Indicted Hardware
- CMUU or CMUL, where the CPU is mounted, is the first suspect. The XBUQ is the second suspect.
For M12-2S system with 2 CPU chip in a box, configuration of PCIe fabric will be changed triggered by CPU chip deconfiguration. This is taken place when ioreconfigure is set to true by setpparmode command.
Configuration of PCIe fabric is changed to maintain access to all the onboard devices and PCIe slots even when either CMUU or CMUL is deconfigured.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)