Asset ID: |
1-79-2219071.1 |
Update Date: | 2017-09-12 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2219071.1
:
M12-device.fan.toofast - Rotation speed of a fan has risen above the threshold.
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-device.fan.toofast
Fujitsu fault codes:
01911026, 01911027, 01911028, 01911029, 0191102a, 0191102b
Details
Type
- Hardware Fault
- device.fan.toofast
Severity
- Major
Description
-
Fault due to the rotation speed of a fan rising above a threshold.
Automated Response
- No action is taken (other than the fault being logged). However, the platform administrator should schedule a service action.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The fan or PSU is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment