Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1523796.1
Update Date:2017-03-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1523796.1 :   SCF-8008-V0 - Correctable errors on the interface between XB chip and CPU chip exceed an acceptable threshold.  


Related Items
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: SCF-8008-V0

Details

Type

Hardware Fault
   fault.chassis.Athena-Server.if.ce-xb-cpu

Severity

Minor

Description

The number of correctable errors on the interface between XB chip and CPU chip has exceeded an acceptable threshold.

Automated Response

The bus lanes between XB chip and CPU chip are deconfigured. The peak performance of the bus is reduced.

Impact

There is a deterioration of peak performance for the bus.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.