Upset due to the fact that PPAR(s) cannot be configured successfully.
The reasons that the PPAR(s) could not be configured:
- no-ppar: 018A0020 Either the system has no PPAR or all the PPARs in the system has been deconfigured due to a prior fault;
- no-lsb: 018A0010, 018A0030, 018AF041, 018AF042, 018AF061, 018AF062, 018AF067, 018AF0C0 Either the PPAR has no LSB or all the LSBs in the PPAR have been deconfigured due to a prior fault;
- no-mem: 018AF064, 018AF065 Either the LSB has no memory or all the memory in the LSB has been deconfigured due to a prior fault;
- no-cpu: 018AF063 Either the LSB has no CPU chip or all the CPU chips in the LSB have been deconfigured due to a prior fault;
- no-xb-for-ppar: 018A0031 Either the system does not have appropriate XB-Box or interconnect between BBs, which is required to form the PPAR, or is entirely deconfigured due to a prior fault;
- faulty-component: 02000e05 There is a component in the LSB that has been diagnosed as faulty, and the configuration rules for this domain do not allow LSBs with faulty components;
- no-mem-for-hv-for-bb:02002c00 The LSB does not have enough memory to start Hypervisor on the LSB by deconfiguration due to a prior fault;
- no-mem-for-hv: 02002c01, 02002c02, 02002c03 The PPAR does not have enough memory to start Hypervisor on the PPAR by deconfiguration due to a prior fault.