Asset ID: |
1-79-2218779.1 |
Update Date: | 2017-05-23 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218779.1
:
M12-vllc.test - Fail-safe-protection circuit fault on start up of PPAR
Related Items |
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-vllc.test
Fujitsu fault codes:
018B0040, 018B0041
Details
Type
- Hardware Fault
- vllc.test
Severity
- Major
Description
-
A fault is detected while testing the fail-safe-protection circuit on starting a PPAR.
This protection circuit manages an event as described in:
M12-env.temp.over-fatal - An overtemperature condition is detected at a temperature sensor (Doc ID 2218810.1)
Automated Response
- For M12-2 systems, the platform will not be powered up.
For M12-2S systems, the building block will not be powered up
Impact
- Nothing is deconfigured, but the platform (M12-2) or building block (M12-2S) will fail to power up.
Indicted Hardware
- The CMU is specified as a suspect.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment