Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2219064.1
Update Date:2017-05-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2219064.1 :   M12-upset_config.xbu - A fault occurred during powerup  


Related Items
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: M12-upset_config.xbu

Fujitsu fault code:

018AF0A0, 018AF0A2

Details

Type

Hardware Fault
   upset_config.xbu

Severity

Major

Description

A fault occurred during powerup (either at connecting power to a box or initial powerup of PPAR) because an XBU was not detected by an XB-Box.

Automated Response

The box is powered down.

Impact

Nothing is deconfigured.

Indicted Hardware

The XBU is most probably not faulty, just misconfigured.

Suggested Action for System Administrator

Configure the XB-Box to XBU connections in accordance with instructions in the SPARC M12 Systems Installation Guide at docs.oracle.com.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback