M12-cpu.se-uncertain - Uncorrectable error detected by a SPARC64 XII CPU chip
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-cpu.se-uncertain
Fujitsu fault codes:
15012000, 15012001, 01A70240, 01A70341
Details
Type
- Hardware Fault
- cpu.se-uncertain
Severity
- Major
Description
-
Fault due to a uncorrectable error detected by a SPARC64 XII CPU chip within the CPU itself.
The domain will experience an uncorrectable error trap due to this fault.
Automated Response
- No immediate action is taken. The uncorrectable error trap may cause the domain to panic.
Impact
-
Nothing is deconfigured. The diagnosis for this fault is certain enough to mark the CPU chip as faulty, but not certain enough to actually deconfigure the CPU chip.
Indicted Hardware
- For M12-1 systems, the Motherboard is marked for replacement. For M12-2 and M12-2S systems, the related Motherboard (CMUU or CMUL) is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)