Solution Type  Predictive Self-Healing Sure

Solution  2244775.1 :   M12-jtag.device - JTAG write failure to a specific chip  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message IDs: M12-jtag.device

Fujitsu fault codes:

01920203, 01920212, 01920213

Details

Type

Hardware Fault
   jtag.device

Severity

Major

Description

Fault due to a JTAG write failure to a specific chip.

The JTAG write operation is performed when configuring the chips. JTAG is used to access CPU chips, or XB chips on XBU.

Automated Response

If this fault takes place while the platform is powering up or while a FRU is powering up, then the FRU with the chip will not be configured into the system.

Otherwise, no immediate action is taken. The platform administrator should schedule a service action.

Impact

If the chip being accessed is a CPU chip: The CPU chip is deconfigured when the PPAR using the CPU chip reboots.

If the chip being accessed is an XB chip: An XB way of PPARs which are using this XB chip is deconfigured.

Indicted Hardware

If the chip being accessed is a CPU chip:

For M12-1 systems, the MBU is marked for replacement.

For M12-2/M12-2S systems:

The CMUU or CMUL, where the faulty CPU chip is mounted, is marked for replacement. If the first suspect is CMUU, there is a small chance that MBC on CMUL is faulty.

If the chip being accessed is a XB chip:

For M12-2S systems, the XBUQ is marked for replacement. There is small chance that MBC on CMUL is faulty.

For XB-Box, the XBUX is marked for replacement. There is small chance that MBC on XSCFUX is faulty.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)