Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218988.1
Update Date:2017-10-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218988.1 :   M12-i2c.device.seeprom-corrupt - XSCF firmware found invalid SEEPROM checksums  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu SPARC M12-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2S
Fujitsu SPARC M12-2
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-i2c.device.seeprom-corrupt

Fujitsu fault code:

018B0002

Details

Type

Hardware Fault
   i2c.device.seeprom-corrupt

Severity

Major

Description

XSCF firmware found invalid checksums of data written in an SEEPROM on a FRU while firmware probes the FRU at starting up of the XSCF, or the FRU is added by addfru or replacefru command.

Automated Response

No immediate action is taken.

Impact

The FRU is deconfigured.

Indicted Hardware

The FRU where the faulty SEEPROM is mounted is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.