Asset ID: |
1-79-2218988.1 |
Update Date: | 2017-10-17 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218988.1
:
M12-i2c.device.seeprom-corrupt - XSCF firmware found invalid SEEPROM checksums
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2S
- Fujitsu SPARC M12-2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-2
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-i2c.device.seeprom-corrupt
Fujitsu fault code:
018B0002
Details
Type
- Hardware Fault
- i2c.device.seeprom-corrupt
Severity
- Major
Description
-
XSCF firmware found invalid checksums of data written in an SEEPROM on a FRU while firmware probes the FRU at starting up of the XSCF, or the FRU is added by addfru or replacefru command.
Automated Response
- No immediate action is taken.
Impact
- The FRU is deconfigured.
Indicted Hardware
- The FRU where the faulty SEEPROM is mounted is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment