Asset ID: |
1-79-2219032.1 |
Update Date: | 2017-10-17 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2219032.1
:
M12-i2c.device.seeprom-corrupt_pcibox - Invalid data checksums in a FRU SEEPROM in a PCI expansion box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-i2c.device.seeprom-corrupt_pcibox
Fujitsu fault codes:
11000026, 11000058, 11000059, 1100005A
Details
Type
- Hardware Fault
- i2c.device.seeprom-corrupt_pcibox
Severity
- Major
Description
-
PCI expansion box firmware found invalid data checksums written to SEEPROM on a FRU as firmware probes the FRU during startup of the PCI expansion box.
This fault is detected on a link board, IOB, FANBP, or PSU in a PCI expansion box.
Automated Response
- No immediate action is taken.
Impact
- The FRU is deconfigured.
Indicted Hardware
- The FRU, where this faulty SEEPROM is mounted, is marked for replacement
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment