Solution Type  Predictive Self-Healing Sure

Solution  2219054.1 :   M12-io.pciex.pcibox.se_linkcable - Error detected on a link cable connecting a link card and a PCI expansion box  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-io.pciex.pcibox.se_linkcable

Fujitsu fault codes:

11000044, 11000049

Details

Type

Hardware Fault
   io.pciex.pcibox.se_linkcable

Severity

Major

Description

Fault due to a serious error detected on a link cable connecting a link card and a PCI expansion box.

This fault is also detected when the cable is removed.

Automated Response

No immediate action is taken. Solaris on a domain using this PCI expansion box may panic, or FMA running on Solaris will take appropriate action.

If the domain does stay up, the domain does not require immediate attention.

The platform administrator should also schedule a service action

Impact

Nothing is deconfigured.

Indicted Hardware

The link cable is specified as faulty. There is a chance that the link cable is not inserted firmly.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)