Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218399.1
Update Date:2017-08-21
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218399.1 :   M12-cpu.ce - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu SPARC M12-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Scope
Details
References


Applies to:

Fujitsu SPARC M12-2 - Version All Versions and later
Fujitsu SPARC M12-2S - Version All Versions and later
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-cpu.ce

Fujitsu fault codes:

15014400, 15014401, 15014402, 15014403, 15014404, 15014405,
15014406, 15014407, 15014408, 15014409, 1501440c, 1501440d,
1501440e, 1501440f, 15014410

Scope

 

Details

Type

Hardware Fault
   cpu.ce

Severity

Major

Description

Fault due to constant correctable errors detected by a SPARC64 XII CPU chip within itself.

Automated Response

No immediate action is taken. The administrator should ensure that the affected CPU is removed from the domain configuration.

Impact

All future interrupts that would cause this fault are blocked.  The domain that is using the CPU chip does not require immediate attention, but the platform administrator should make some sort of arrangement to make sure the domain does not use the CPU chip for an extended period of time.  If the error code is 15014406 or 15014407, frequency of correctable error is serious enough to deconfigure the CPU chip the next time the domain reboots.

For M12-1 systems, this means the platform becomes unbootable.



Indicted Hardware

For M12-1 systems the Motherboard is marked for replacement. For M12-2 and M12-2S systems, the related Motherboard (CMUU or CMUL) is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.