Asset ID: |
1-79-1523769.1 |
Update Date: | 2017-03-23 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1523769.1
:
SCF-8008-SN - A data compare error has been detected within a CPU MAC when memory is in mirror mode
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: SCF-8008-SN
Details
Type
- Hardware Fault
- fault.chassis.Athena-Server.memory.mirror.ue
Severity
- Major
Description
-
A data compare error has been detected within a CPU MAC when memory is in mirror mode.
Automated Response
- The memory associated with the CPU MAC will be deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
Impact
-
The domain will receive an uncorrectable error trap which may cause the domain to panic.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment