Asset ID: |
1-79-2218776.1 |
Update Date: | 2017-09-12 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218776.1
:
M12-device.misconfig_psu - An incorrect PSU was detected in a box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-device.misconfig_psu
Fujitsu fault code:
018A0050, 018AF023, 018AF024
Details
Type
- Hardware Fault
- device.misconfig_psu
Severity
- Major
Description
-
A fault occurred when an incorrect PSU was detected.
Automated Response
- The powerup request is rejected.
Impact
- The server or XB-Box is deconfigured.
Indicted Hardware
- The PSU is marked for replacement. It is possible that an unsupported (unknown) PSU is installed. The part number of the indicted PSU should be obtained and compared to the Fujitsu FRU inventory for the particular server or XB-Box in question.
Suggested Action for System Administrator
- The indicted PSU should be removed from the server or XB-Box. It is possible the server or XB-Box will power up once the indicted PSU is removed.