Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218763.1
Update Date:2017-05-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218763.1 :   M12-device.missing_xbu_ddc - A DDC on an XBUQ in M12-2S or an XBUX in XB-Box is missing or could not be detected  


Related Items
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: M12-device.missing_xbu_ddc

Fujitsu fault code:

018AF0A1

Details

Type

Hardware Fault
   device.missing_xbu_ddc

Severity

Major

Description

A fault occurred during powerup where a DDC on an XBUQ in M12-2S or an XBUX in XB-Box is missing or could not be detected.

Automated Response

No immediate action will be taken.

For M12-2S servers, the PPAR continues power-on sequence with this building block deconfigured.

For XB-Box, the PPAR continues power-on sequence with this XB-Box deconfigured.

Impact

For M12-2S servers, the building block becomes unbootable.

For XB-Box, the XB-Box becomes unbootable.

Indicted Hardware

The XBUQ in M12-2S or XBUX in XB-Box is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)