Asset ID: |
1-79-2218982.1 |
Update Date: | 2017-05-26 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218982.1
:
M12-xb.ce - Persistent correctable errors detected in the logic internal to an XB chip
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-xb.ce
Fujitsu fault codes:
15066000, 15066001, 15066002, 15066003, 15066004, 15066005,
15066006, 15066007, 15066200, 15066201, 15066202, 15066203,
15066204, 15066205, 15066206, 15066207, 15066208, 15066209
Details
Type
- Hardware Fault
- xb.ce
Severity
- Major
Description
-
Fault due to persistent correctable errors detected in the logic internal to an XB chip.
Automated Response
- No immediate action will be taken.
Impact
- An XB-way is deconfigured when all the PPARs using the faulty XB chip are stopped.
Indicted Hardware
- XBUQ or XBUX where suspicious XB chip is mounted is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments