Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2219070.1
Update Date:2017-10-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2219070.1 :   M12-Testalert - A test fault and associated SNMP trap have been generated on an M12 server or XB-Box  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message IDs: M12-Testalert

Fujitsu fault code:

FF020001

Details

Type

Hardware Fault
   Testalert

Severity

Minor

Description

It is possible to create a test fault and SNMP trap from the XSCF command line or BUI to check functionality of the M12 system fault reporting mechanism:

XSCF> rastest -c test

This will generate an error message that can be viewed with the showlogs error XSCF command, and, if SNMP is enabled on the XSCF, a test trap will be forwarded to any designated traphost(s).

XSCF> showlogs error
Date: Jul 10 09:21:25 PDT 2016
    Code: 80000000-003e01009301009600-ff0200010000000000000000
    Status: Alarm                  Occurred: Jul 10 09:21:21.666 PDT 2016
    FRU: /BB#0/CMUL,/BB#0/OPNL,/BB#0/PSU#0
    Msg: Pseudo error for test trap notice

The test trap will look something like this, for SNMP v2c:

2016-07-10 12:21:30 servername.customer.com [192.168.0.1]:

iso.3.6.1.2.1.1.3.0 = Timeticks: (131190664) 15 days, 4:25:06.64
iso.3.6.1.6.3.1.1.4.1.0 = OID:
iso.3.6.1.4.1.211.1.15.4.1.2.0.1
iso.3.6.1.4.1.211.1.15.4.1.1.12.2.1.13.1.0.2.0.254.0 = INTEGER: 3
iso.3.6.1.4.1.211.1.15.4.1.2.1.2.0 = INTEGER: 1
iso.3.6.1.4.1.211.1.15.4.1.1.4.3.0 = STRING: "PZ51650019"
iso.3.6.1.4.1.211.1.15.4.1.1.4.2.0 = STRING: "SPARC M12-2S"
iso.3.6.1.4.1.211.1.15.4.1.1.4.1.0 = STRING: "servername"
iso.3.6.1.4.1.211.1.15.4.1.2.1.14.0 = STRING: "FF020001"
iso.3.6.1.4.1.211.1.15.4.1.2.1.15.0 = STRING: "Jul 10 09:21:21.666 PDT 2016"
iso.3.6.1.4.1.211.1.15.4.1.2.1.16.0 = STRING: "https://support.oracle.com/msg/M12-Testalert
iso.3.6.1.4.1.211.1.15.4.1.2.1.17.0 = STRING: "PP164908V1  "
iso.3.6.1.4.1.211.1.15.4.1.2.1.18.0 = STRING: "CA07855-D301 A5   /BGA-16CL-02          "
iso.3.6.1.4.1.211.1.15.4.1.2.1.19.0 = STRING: "PP1649029V  "
iso.3.6.1.4.1.211.1.15.4.1.2.1.20.0 = STRING: "CA20365-B35X 006AC/7060922        "
iso.3.6.1.4.1.211.1.15.4.1.2.1.21.0 = STRING: "HWCD1622000389"
iso.3.6.1.4.1.211.1.15.4.1.2.1.22.0 = STRING: "CA01022-0850/7334651                         "
iso.3.6.1.4.1.211.1.15.4.1.2.1.23.0 = STRING: "/BB#0/CMUL,/BB#0/OPNL,/BB#0/PSU#0"
iso.3.6.1.4.1.211.1.15.4.1.2.1.24.0 = STRING: "Fujitsu M12-2S"
iso.3.6.1.4.1.211.1.15.4.1.2.1.25.0 = INTEGER: 1
iso.3.6.1.4.1.211.1.15.4.1.2.1.26.0 = STRING: "M12-Testalert"


Automated Response

Depending on whether ASR Manager or Enterprise Manager OpsCenter is configured as the traphost destination, an email notification will be sent and a test event generated, but no SR creation will occur.

Impact

No hardware is degraded or marked as faulty. This is purely a test mechanism and has no impact on system operation.

Indicted Hardware

None.

Suggested Action for System Administrator

No action for this event is required.

System Administrators should reference the document Fujitsu SPARC M12 Systems System Operation and Administration Guide on docs.oracle.com for instructions on setting-up and testing SNMP configurations.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback