Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218387.1
Update Date:2017-08-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218387.1 :   M12-memory.block.mirror.ue - A data compare error has been detected when memory is in mirror mode  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-memory.block.mirror.ue

Fujitsu fault codes:

15030200, 15030201, 15030202, 15030203, 15030204, 15030205

Details

Type

Hardware Fault
   memory.block.mirror.ue

Severity

Critical

Description

Fault due to a data compare error when memory is in mirror mode, detected by the CPU chip hardware.

Automated Response

No immediate action is taken by XSCF. It is expected that the domain will take appropriate action.

Impact

The DIMMs forming the mirroring pair where the compare error is detected are deconfigured (8 DIMMs total) after the domain using the affected memory reboots. The domain will get a memory uncorrectable error (UE) trap.

Indicted Hardware

For M12-2/M12-2S systems, the CMUU or CMUL is marked for replacement. For M12-1 systems, the MBU is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.