Solution Type  Predictive Self-Healing Sure

Solution  2218787.1 :   M12-env.temp.over - An overtemperature condition is detected by a temperature sensor  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-env.temp.over

Fujitsu fault codes:

01910810, 01910910, 01910A10, 01910B10, 01910C10, 01910D10,
01910D12, 01911111, 11000036

Details

Type

Hardware Fault
   env.temp.over

Severity

Minor

Description

Fault due to an overtemperature condition detected by a temperature sensor.

The overtemperature condition was detected by:

- An inlet temperature sensor

- An exhaust temperature sensor

- A temperature sensor located near a:

  - CPU

  - DIMM

  - XB chip

  - PCI express switch chip

  - SAS chip

  - DDC

The sensor could also be located on an XB-Box or PCI expansion box.

The temperature detected is not high enough to affect the operation of domains on the platform.

Automated Response

Raise the fan speed to high for all fans operating at normal speed (including the fans in the PSUs) on the box where high temperature is detected. The platform administrator should check for the cause of the overtemperature condition.

Impact

Nothing is deconfigured.

Indicted Hardware

The suspect is the external environment.

Suggested Action for System Administrator

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)