Asset ID: |
1-79-2218981.1 |
Update Date: | 2017-05-26 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218981.1
:
M12-if.fe-asic-clk_xbu_xb - Fatal clock distribution error detected by a XB chip
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S
SPARC
Purpose
Provide additional information for message ID: M12-if.fe-asic-clk_xbu_xb
Fujitsu fault codes:
15067000, 15067001, 15067002, 15067003
Details
Type
- Hardware Fault
- if.fe-asic-clk_xbu_xb
Severity
- Major
Description
-
Fault due to a fatal clock distribution error detected by a XB chip.
Automated Response
- PPARs using this XB chip are reset.
Impact
- The XBU is deconfigured.
An XB-way is deconfigured on PPARs that are using this XB chip.
Indicted Hardware
- XBU, where this XB chip is mounted, is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment