M12-power.power-off_pcibox_psu - XSCF failed to turn off the power to a PSU in a PCI expansion Box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu M10 PCI Expansion Unit
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-power.power-off_pcibox_psu
Fujitsu fault codes:
1100001C, 1100001D
Details
Type
- Hardware Fault
- power.power-off_pcibox_psu
Severity
- Major
Description
-
A fault occurred when the XSCF tried to turn off the power to a PSU in a PCI expansion Box.
Automated Response
- No immediate action is taken because of this fault, and the poweroff sequence continues. The platform administrator should schedule a service action.
Impact
- The PSU is deconfigured. If enough PSUs are now non-operational, the PCI expansion box will not start.
Indicted Hardware
- The PSU is marked for replacement. There is a slight chance the IOB is at fault.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)