Solution Type  Predictive Self-Healing Sure

Solution  1523786.1 :   SCF-8008-PW - The number of intermittent correctable memory errors (ICEs) has exceeded an acceptable threshold  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10-4
Fujitsu M10-4S
Fujitsu M10-1
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: SCF-8008-PW

Details

Type

Hardware Fault
   fault.chassis.Athena-Server.memory.page.ice

Severity

Minor

Description

The number of intermittent correctable memory errors (ICEs) has exceeded an acceptable threshold.

Automated Response

An attempt will be made to remove this memory page from service.

Impact

The performance of the system may be minimally impacted as a result of removing the memory page from operation.

Suggested Action for System Administrator

No repair action is recommended at this time.