Solution Type  Predictive Self-Healing Sure

Solution  2218782.1 :   M12-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-device.misconfig_pcibox_psu

Fujitsu fault codes:

1100001E, 1100001F, 11000020

Details

Type

Hardware Fault
   device.misconfig_pcibox_psu

Severity

Major

Description

A fault occurred where an incorrect PSU was detected in a PCI Expansion Unit.

Automated Response

The powerup request for the PCI Expansion Unit is rejected.

Impact

The PCI Expansion Unit is deconfigured.

Indicted Hardware

The PSU is marked for replacement. It is possible that an unsupported (unknown) PSU is mounted. The part number of the indicted PSU should be obtained and compared to the Fujitsu FRU inventory for the PCI Expansion Unit.

Suggested Action for System Administrator

The indicted PSU should be removed from the PCI Expansion Unit. It is possible the PCI Expansion Unit will power up once the indicted PSU is removed.