Asset ID: |
1-79-2218782.1 |
Update Date: | 2017-09-12 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218782.1
:
M12-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10 PCI Expansion Unit
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-device.misconfig_pcibox_psu
Fujitsu fault codes:
1100001E, 1100001F, 11000020
Details
Type
- Hardware Fault
- device.misconfig_pcibox_psu
Severity
- Major
Description
-
A fault occurred where an incorrect PSU was detected in a PCI Expansion Unit.
Automated Response
- The powerup request for the PCI Expansion Unit is rejected.
Impact
- The PCI Expansion Unit is deconfigured.
Indicted Hardware
- The PSU is marked for replacement. It is possible that an unsupported (unknown) PSU is mounted. The part number of the indicted PSU should be obtained and compared to the Fujitsu FRU inventory for the PCI Expansion Unit.
Suggested Action for System Administrator
- The indicted PSU should be removed from the PCI Expansion Unit. It is possible the PCI Expansion Unit will power up once the indicted PSU is removed.

Attachments
This solution has no attachment