M12-power.warning_pcibox_psu - Undervoltage Warning or Overvoltage Warning on a Power Supply in PCI Expansion Box
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-power.warning_pcibox_psu
Fujitsu fault code:
11000006
Details
Type
- Hardware Fault
- power.warning_pcibox_psu
Severity
- Major
Description
-
A fault occurred due to an undervoltage warning or overvoltage warning detected on a PSU in a PCI expansion box.
Automated Response
- No action is taken because of this warning. However, the platform administrator should schedule a service action.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The PSU is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments