Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2242784.1
Update Date:2017-08-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2242784.1 :   M12-cpu.core.strand.ce-quiet - Persistent correctable errors (CEs) detected by a SPARC64 XII CPU chip  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu SPARC M12-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2S
Fujitsu SPARC M12-2
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-cpu.core.strand.ce-quiet

Fujitsu fault codes:

15014500, 15014501, 15014502, 15014503, 15014504, 15014505,
15014506, 15014507, 15014508, 15014509, 1501450a, 1501450b,
1501450c, 1501450d, 1501450e

Details

Type

Hardware Fault
cpu.core.strand.ce-quiet

Severity

Minor

Description

Fault that indicates too many correctable faults (cpu.core.strand.ce) within CPU strand(s) have occurred.
Future occurrences of such correctable faults are blocked.

Automated Response

No immediate action is taken. Additionally, all future such core correctable error interrupts to service processor are blocked.  The platform administrator should make some sort of arrangement to make sure the domain does not use the CPU chip for an extended period of time

Impact

Nothing will be deconfigured.

Indicted Hardware

For M12-1 systems, the MBU is marked for replacement.
For M12-2 and M12-2S systems, the related Motherboard (CMUU or CMUL) is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback