Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2243519.1
Update Date:2017-05-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2243519.1 :   M12-device.misconfig_xbbp - An Invalid XBBP has been Detected  


Related Items
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu SPARC M12-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu SPARC M12-2 - Version All Versions and later
Fujitsu SPARC M12-2S - Version All Versions and later
SPARC

Purpose

Provide additional information for message ID: M12-device.misconfig_xbbp

Fujitsu fault code:

018AF106

Details

Type

Hardware Fault
   device.misconfig_xbbp

Severity

Major

Description

A fault occurred where an incorrect XBBP was detected in a box.  It is possible that unsupported (unknown) XBBP is installed.

Automated Response

The power-on request for the box is rejected.

Impact

The system is deconfigured

Indicted Hardware

The XBBP is marked for replacement.
The improper XBBP should be removed from the server.

Suggested Action for System Administrator

 The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.  Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback