Asset ID: |
1-79-2218446.1 |
Update Date: | 2017-08-14 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2218446.1
:
M12-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-device.misconfig_cmu_dimm
Fujitsu fault code:
018AF070
Details
Type
- Hardware Fault
- device.misconfig_cmu_dimm
Severity
- Major
Description
-
An error occurred during powerup when a memory configuration rule has been violated.
Automated Response
- No immediate action is taken.
Impact
-
DIMM(s) that have violated memory configuration rules will be deconfigured.
Indicted Hardware
- The affected DIMM(s) is/are marked for replacement. However, experience on previous M-Series platforms indicates that, once correctly configured, the DIMMs in question will function normally.
Suggested Action for System Administrator
- Refer to the memory configuration rules outlined in the relevant SPARC M12 Service Manual for your system.

Attachments
This solution has no attachment