Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2218446.1
Update Date:2017-08-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2218446.1 :   M12-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated  


Related Items
  • Fujitsu SPARC M12-1
  •  
  • Fujitsu SPARC M12-2
  •  
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC

Purpose

Provide additional information for message ID: M12-device.misconfig_cmu_dimm

Fujitsu fault code:

018AF070

Details

Type

Hardware Fault
   device.misconfig_cmu_dimm

Severity

Major

Description

An error occurred during powerup when a memory configuration rule has been violated.

Automated Response

No immediate action is taken.

Impact

DIMM(s) that have violated memory configuration rules will be deconfigured.

Indicted Hardware

The affected DIMM(s) is/are marked for replacement. However, experience on previous M-Series platforms indicates that, once correctly configured, the DIMMs in question will function normally.

Suggested Action for System Administrator

Refer to the memory configuration rules outlined in the relevant SPARC M12 Service Manual for your system.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.