Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2243874.1
Update Date:2017-05-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2243874.1 :   M12-config.xbbox - A fault occurred during powerup  


Related Items
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu SPARC M12-2S
SPARC

Purpose

Provide additional information for message ID: M12-config.xbbox

Fujitsu fault code:

018AF0E0, 018AF0E1, 018AF0E2

Details

Type

Hardware Fault
   config.xbbox

Severity

Major

Description

A failure occurred during powerup (at connecting power to a xb-box) because the XB board(s) in the XB-box was/were not detected.

Automated Response

No action is taken; the powerup proceeds normally without failed XB board(s).

Impact

The failed XB board is deconfigured.

Indicted Hardware

The XB board is the suspect. There is a chance that the XB board is not inserted firmly.

Suggested Action for System Administrator

To recover from this issue remove the AC power from the system for 30 seconds then re-apply power.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

 

 