Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2243875.1
Update Date:2017-05-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2243875.1 :   M12-upset_config.bbid - On powerup a Building Block ID does not match the connected BB control cable  


Related Items
  • Fujitsu SPARC M12-2S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu SPARC M12-2S - Version All Versions and later
SPARC

Purpose

Provide additional information for message ID: M12-upset_config.bbid

Fujitsu fault code:

01A10010, 01A10011

Details

Type

Hardware Fault
   upset_config.bbid

Severity

Major

Description

An upset occurred during powerup (either at connecting power to a box or initial powerup of Ppar) because the connection of BB control cable does not match to assigned BB-ID.

Automated Response

No action is taken; the powerup proceeds normally without wrongly connected BB.

Impact

The building block is deconfigured.

Indicted Hardware

There is a chance that either the BB-ID was wrongly configured at first power-up of the BB or the BB control cable is not connected properly.

Suggested Action for System Administrator

To recover from this issue remove the AC power from the system for 30 seconds then re-apply power.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback