M12-upset_config.bbid - On powerup a Building Block ID does not match the connected BB control cable
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2S - Version All Versions and later
SPARC
Purpose
Provide additional information for message ID: M12-upset_config.bbid
Fujitsu fault code:
01A10010, 01A10011
Details
Type
- Hardware Fault
- upset_config.bbid
Severity
- Major
Description
-
An upset occurred during powerup (either at connecting power to a box or initial powerup of Ppar) because the connection of BB control cable does not match to assigned BB-ID.
Automated Response
- No action is taken; the powerup proceeds normally without wrongly connected BB.
Impact
- The building block is deconfigured.
Indicted Hardware
- There is a chance that either the BB-ID was wrongly configured at first power-up of the BB or the BB control cable is not connected properly.
Suggested Action for System Administrator
- To recover from this issue remove the AC power from the system for 30 seconds then re-apply power.
- Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)