Asset ID: |
1-79-2243546.1 |
Update Date: | 2017-08-14 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2243546.1
:
M12-power.undervoltage_pcibox_iob - Undervoltage failure on an IOB in PCI Expansion Box.
Related Items |
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
- Fujitsu SPARC M12-2S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu SPARC M12-2
Fujitsu SPARC M12-2S
Fujitsu SPARC M12-1
SPARC
Purpose
Provide additional information for message ID: M12-power.undervoltage_pcibox_iob
Fujitsu fault code:
11000007, 11000008, 11000009, 1100000A, 1100000B, 1100000C,
1100000D
Details
Type
- Hardware Fault
- power.undervoltage_pcibox_iob
Severity
- Major
Description
-
A fault occurred due to a serious undervoltage failure from an IOB in PCI expansion Box.
Automated Response
- The PCI expansion box is powered off, and the ppar using this PCI expansion box is powered-off, as well. The PCI expansion box cannot be powered back on.
Impact
-
The PCI expansion box is deconfigured.
Indicted Hardware
- The IOB is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment