| Reference
|
Synopsis
|
Last Modified Date
|
| 2247050.1 |
M10-upset.config.bbid - On powerup a Building Block ID does not match the connected BB control cable |
2017-03-22
|
| 2241115.1 |
How to deal/recover from a hung/unresponsive Physical Partition (PPAR) or Guest Domain |
2017-10-11
|
| 2077216.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: Integration of an Flash Accelerator F160 NVMe Card (Aura 3 NVMe) at a glance |
2018-05-09
|
| 2060087.1 |
M10-4S XSCF can report a self diagnosis warning detection fault every 10 days |
2016-01-05
|
| 1934739.1 |
CVE-2014-7169, CVE-2014-6271, CVE-2014-7186, CVE-2014-7187, CVE-2014-6277 and CVE-2014-6278 Patch Availability Document for Fujitsu M10-x Service Processor (XCP) |
2017-10-11
|
| 1933615.1 |
M10-device.fan.tooslow@pcibox - The rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) is incorrect |
2016-01-06
|
| 1933601.1 |
M10-device.fan.toofast - Rotation speed of a fan has risen above the threshold. |
2016-01-06
|
| 1907465.1 |
SPARC LDOM CLI Cheat Sheet |
2017-12-15
|
| 1678458.1 |
M10-Heartbeat - A heartbeat SNMP trap has been generated on an M10 server or XB-Box |
2016-01-06
|
| 1629173.1 |
Fujitsu M10-1/M10-4/M10-4S Customer Actions: PPAR Down |
2014-08-04
|
| 1629165.1 |
Fujitsu M10-1/M10-4/M10-4S Customer Actions: All PPARs Down |
2014-08-04
|
| 1629162.1 |
Fujitsu M10-4S Customer Actions: Multiple PPAR Down |
2014-08-04
|
| 1629160.1 |
Fujitsu M10-1/M10-4/M10-4S Customer Actions: Fru Configured out of Solaris |
2017-08-23
|
| 1598634.1 |
Fujitsu M10-1/M10-4/M10-4S Fan / Fantray temperature and failure behavior |
2017-06-01
|
| 1594351.1 |
M10-upset_config_opnl - Operator Panel (OPNL) not detected during powerup |
2015-12-31
|
| 1594335.1 |
M10-config.xbbox_xbbox_xbu - A fault occurred during powerup |
2017-03-22
|
| 1594296.1 |
M10-upset_config_xbu - A fault occurred during powerup |
2016-01-06
|
| 1579921.1 |
Installation configuration information CD for M10 systems |
2018-03-07
|
| 1571505.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_ppar.config |
2013-10-14
|
| 1571504.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_domain.post |
2013-10-14
|
| 1571503.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_domain.panic |
2015-01-12
|
| 1571502.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_config.power |
2013-10-14
|
| 1571501.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_config.linkcable_pcibox_linkbrd_linkcable |
2013-10-14
|
| 1571499.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_config_xbu |
2013-10-30
|
| 1571498.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-unmatch_xbbox-id Instructions |
2013-10-14
|
| 1571497.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-env.temp.over-fail Instructions |
2013-10-14
|
| 1571496.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.missing_psu Instructions |
2013-10-14
|
| 1571495.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.missing_pcibox_linkbrd_linkcable |
2013-10-14
|
| 1571494.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig_pcibox_psu |
2013-10-14
|
| 1571493.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig_cmu_dimm |
2013-10-14
|
| 1571441.1 |
Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig Instructions |
2013-10-15
|
| 1570038.1 |
M10-upset.config.xbbox - A problem occurred during powerup |
2016-01-04
|
| 1567334.1 |
M10-Testalert - A test fault and associated SNMP trap have been generated on an M10 server or XB-Box |
2016-01-06
|
| 1539402.1 |
M10-upset_pcibox.firmware - A hard-to-diagnose failure of the PCI expansion box occurred |
2015-12-31
|
| 1539401.1 |
M10-upset_config.linkcable_pcibox_linkbrd_linkcable - An upset occurred during powerup |
2016-01-04
|
| 1539398.1 |
M10-device.missing_pcibox_linkbrd_linkcable - PCI expansion box link cable not connected |
2015-12-30
|
| 1537682.1 |
M10-upset_config.fan_pcibox - The number of fans in a PCI expansion box are insufficient |
2015-12-31
|
| 1537679.1 |
M10-i2c.device_pcibox_linkbrd_linkcable - I2C access failure to I2C devices on a link cable when starting a PCI expansion box |
2016-01-06
|
| 1537513.1 |
M10-i2c.device_pcibox_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) |
2015-12-30
|
| 1537511.1 |
M10-i2c.device_pcibox_linkbrd - I2C access failure to I2C devices on an link board in a PCI expansion box |
2017-03-21
|
| 1537510.1 |
M10-i2c.device_pcibox_fanbp - I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box |
2017-03-21
|
| 1537507.1 |
M10-i2c.device_linkcard - I2C access failure to I2C devices on the link card |
2015-12-30
|
| 1537504.1 |
M10-io.pciex.linkcard.flash - Problem detected writing to flash memory on a link card |
2015-12-31
|
| 1537492.1 |
M10-io.pciex.pcibox.se_linkcable - Error detected on a link cable connecting a link card and a PCI expansion box |
2015-12-31
|
| 1537490.1 |
M10-io.pciex.pcibox.se_iob - Error detected on an IOB in a PCI expansion box |
2015-12-31
|
| 1537488.1 |
M10-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box |
2015-12-31
|
| 1537486.1 |
M10-io.pciex.pcibox.fe_slot - Fatal error detected on a PCI Express slot in a PCI expansion box |
2015-12-31
|
| 1537483.1 |
M10-i2c.device_pcibox_iob - I2C access failure to I2C devices on an IOB in a PCI expansion box |
2015-12-30
|
| 1537480.1 |
M10-io.pciex.pcibox.fe_iob - Fatal error detected on a IOB in a PCI expansion box |
2015-12-31
|
| 1537479.1 |
M10-io.pciex.pcibox.fe - Fatal error detected on a linkcard in a PCI slot or a linkbrd in a PCI expansion box |
2015-12-31
|
| 1537478.1 |
M10-lrci - An error was detected by an LRCI supported device connected via LAN |
2017-03-21
|
| 1537476.1 |
M10-madm.io.fe - MADM software running on the domain has detected an IO problem |
2015-12-31
|
| 1537474.1 |
M10-madm.io.se - MADM software running on the domain has detected a serious IO problem |
2015-12-31
|
| 1537469.1 |
M10-domain.fe-unexpected-trap - An unexpected trap with unknown cause was detected by a CPU chip on a PPAR |
2015-12-30
|
| 1537466.1 |
M10-upset_domain.post - POST may not be running correctly in a domain |
2015-12-31
|
| 1537464.1 |
M10-upset_ppar.config - PPAR(s) cannot be configured successfully |
2015-12-31
|
| 1537451.1 |
M10-upset_domain.panic - Solaris panics but the reason is unknown to XSCF software |
2017-10-16
|
| 1537447.1 |
M10-defect_software - XCP software is diagnosed as faulty |
2015-12-30
|
| 1537365.1 |
M10-upset.xscfu - A hard-to-diagnose failure of the XSCF occurred |
2017-03-17
|
| 1537313.1 |
M10-xscfu - A hardware problem has been detected with an XSCFU or PSUBP |
2016-01-06
|
| 1537309.1 |
M10-mbc.ce - Persistent correctable errors detected by an MBC chip within itself |
2015-12-31
|
| 1537090.1 |
M10-mbc.se-dma - Error detected by the XSCF on the DMA interface of an MBC chip |
2017-03-17
|
| 1537087.1 |
M10-mbc.se - Error detected by an MBC chip within itself |
2015-12-31
|
| 1537086.1 |
M10-if.se-mbc-xscf - Error detected on the interface between an MBC chip and the XSCFU or XSCF function on MBU or CMUL |
2015-12-31
|
| 1537079.1 |
M10-mbc.se-cmd - XSCF software-detected problem on the command interface between the XSCF and a MBC chip |
2018-04-19
|
| 1537070.1 |
M10-mbc.fe - Fatal internal error detected by an MBC chip within itself |
2015-12-31
|
| 1537065.1 |
M10-i2c.device.seeprom-corrupt - XSCF firmware found invalid SEEPROM checksums |
2015-12-30
|
| 1536992.1 |
M10-i2c.device - I2C access failure to I2C devices |
2015-12-30
|
| 1536989.1 |
M10-i2c.device_opnl - I2C access failure to I2C devices on the Operator Panel (OPNL) |
2015-12-30
|
| 1536981.1 |
M10-i2c.device-internal - Data compare error on I2C access to a specific chip |
2017-01-12
|
| 1536979.1 |
M10-i2c.device_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) |
2015-12-30
|
| 1536971.1 |
M10-i2c.device_cmu - I2C write failure to a specific chip |
2016-01-06
|
| 1536606.1 |
M10-jtag.device - JTAG write failure to a specific chip |
2017-03-16
|
| 1536605.1 |
M10-if.fe-asic-clk_xbu_xb - Fatal clock distribution error detected by a XB chip |
2015-12-30
|
| 1536589.1 |
M10-if.ce-xb-xbucable - Permanent correctable errors detected at a cable connecting two XB chips |
2015-12-30
|
| 1536563.1 |
M10-xb.test_xbu_xb - Self-test error detected by an XB chip within itself or while trying to establish communication with another XB chip |
2017-03-16
|
| 1536562.1 |
M10-xb.test_cmu_cpu - Self-test error detected by an XB chip within itself or while trying to establish communication with a CPU chip |
2017-03-16
|
| 1536561.1 |
M10-xb.ce - Persistent correctable errors detected in the logic internal to an XB chip |
2015-12-31
|
| 1536525.1 |
M10-if.ce-xb-xb - Permanent correctable errors on the interface between two XB chips |
2015-12-30
|
| 1536512.1 |
M10-if.ce-xb-cpu - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ |
2015-12-30
|
| 1536501.1 |
M10-if.ce-cpu-mbc - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a MBC-chip on a CMUL |
2015-12-30
|
| 1536017.1 |
M10-if.ce-cpu-xb - Permanent correctable errors on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ |
2016-12-29
|
| 1536001.1 |
M10-if.ce-cpu-cpu - Persistent correctable errors on the interface between two CPU chips |
2015-12-30
|
| 1536000.1 |
M10-xb.fe - Fatal internal error detected by an XB chip within itself |
2015-12-31
|
| 1535998.1 |
M10-if.fe-xb-xbucable - Fatal error detected at cable connecting two XB chips |
2015-12-31
|
| 1535997.1 |
M10-if.fe-xb-xb - Fatal error on the interface between two XB chips |
2015-12-31
|
| 1535671.1 |
M10-if.fe-cpu-mbc - Fatal error on the interface between a CPU chip and MBC chip. |
2015-12-30
|
| 1535669.1 |
M10-if.fe-xb-cpu - Fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ |
2015-12-30
|
| 1535608.1 |
M10-if.fe-cpu-xb Fatal error on the interface between a CPU chip on a CMUU or a CMUL and a XB-chip on an XBUQ |
2017-03-06
|
| 1535600.1 |
M10-if.fe-cpu-cpu - Fatal error on the interface between CPU chips. |
2015-12-30
|
| 1535576.1 |
M10-llc.test - Fail-safe-protection circuit fault on start up of PPAR |
2015-12-31
|
| 1535575.1 |
M10-upset_config.fan - The number of fans are insufficient to permit powerup |
2015-12-31
|
| 1535552.1 |
M10-env.temp.over-fatal - An overtemperature condition is detected at a temperature sensor |
2016-12-29
|
| 1535254.1 |
M10-env.temp.over-fail - Overtemperature fault |
2016-02-08
|
| 1535238.1 |
M10-env.temp.over-warn - An overtemperature warning condition is detected by a temperature sensor |
2016-12-21
|
| 1534924.1 |
M10-env.temp.over - An overtemperature condition is detected by a temperature sensor |
2016-01-06
|
| 1534913.1 |
M10-env.temp.under - An undertemperature condition is detected by the inlet temperature sensor |
2015-12-30
|
| 1534912.1 |
M10-device.fan.toofast_pcibox - Rotation speed of a fan has risen above the threshold. |
2015-12-30
|
| 1534907.1 |
M10-device.pump.tooslow_llc - Rotation speed of a Liquid Loop Cooling (LLC) pump is either lower than its predefined threshold or has stopped completely |
2015-12-30
|
| 1534904.1 |
M10-device.fan.tooslow - The rotation speed of a fan (including fans in fan trays or in PSUs) is incorrect |
2016-12-22
|
| 1534882.1 |
M10-env.power.loss - A power supply (PSU) detected a loss of AC power |
2016-01-06
|
| 1534879.1 |
M10-upset_config.power - An upset occurred during powerup |
2015-12-31
|
| 1534828.1 |
M10-device.removed - A FRU's presence detect signal suddenly disappears |
2015-12-30
|
| 1534813.1 |
M10-device.inserted - A FRU's presence is unexpectedly detected |
2015-12-30
|
| 1534811.1 |
M10-device.missing_psu - Unable to start up system because not enough functional PSUs are available |
2015-12-30
|
| 1534810.1 |
M10-device.missing_xbu_ddc - A DDC on an XBUQ in M10-4S or an XBUX in XB-Box is missing or could not be detected |
2015-12-30
|
| 1534809.1 |
M10-device.missing_psubp_ddc - A DDC on a PSUBP in M10-1, M10-4 or M10-4S is missing or could not be detected |
2015-12-30
|
| 1534807.1 |
M10-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box |
2016-12-29
|
| 1534806.1 |
M10-device.misconfig_psu - An incorrect PSU was detected in a box |
2017-03-22
|
| 1534753.1 |
M10-device.misconfig_ddc - An incorrect DDC was detected |
2017-03-22
|
| 1534752.1 |
M10-device.fail_pcibox_psu - A PSU signaled that it has failed |
2015-12-30
|
| 1534751.1 |
M10-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed |
2015-12-30
|
| 1534750.1 |
M10-device.fail_psu - A PSU signaled that it has failed |
2017-08-02
|
| 1534069.1 |
M10-device.fail_ddc - A DDC on a FRU signaled that it has failed |
2015-12-30
|
| 1534068.1 |
M10-power.power-off_pcibox_psu - XSCF failed to turn off the power to a PSU in a PCI expansion Box |
2015-12-31
|
| 1534066.1 |
M10-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB |
2015-12-31
|
| 1534033.1 |
M10-power.power-off - A fault occurred when the XSCF tried to turn off power to a DDC |
2015-12-31
|
| 1533831.1 |
M10-power.overvoltage_pcibox_iob - Overvoltage failure detected on an IOB in PCI expansion Box |
2015-12-31
|
| 1533826.1 |
M10-power.overvoltage - Overvoltage failure |
2015-12-31
|
| 1533822.1 |
M10-power.undervoltage_pcibox_iob - Undervoltage failure from an IOB in PCI expansion Box |
2015-12-31
|
| 1533669.1 |
M10-power.undervoltage - Undervoltage failure |
2015-12-31
|
| 1533667.1 |
M10-power.warning_pcibox_psu - Undervoltage warning or overvoltage warning detected on a PSU in PCI expansion box |
2015-12-31
|
| 1533666.1 |
M10-power.warning_psu - Undervoltage warning or overvoltage warning detected on a PSU |
2016-01-06
|
| 1533664.1 |
M10-power.warning_pcibox_iob - Undervoltage warning or overvoltage warning detected on an IOB in PCI expansion box |
2015-12-31
|
| 1533649.1 |
M10-power.warning - Undervoltage warning or overvoltage warning |
2017-08-02
|
| 1533647.1 |
M10-asic.power.fail - Power failure is detected on an ASIC |
2017-03-22
|
| 1533645.1 |
M10-io.domain.fma - FMA running on a domain detects a PCI Express-related failure, and forwards information to XSCF |
2015-12-31
|
| 1533644.1 |
Failure to boot Solaris on a domain |
2015-09-25
|
| 1533642.1 |
M10-ioc.ch.ce - correctable errors detected by the IOC |
2015-12-31
|
| 1533634.1 |
M10-io.pciex.switch.se - An error was detected within a PCIe switch |
2017-03-27
|
| 1533204.1 |
M10-io.pcie.device.se - An error was detected on a PCIe switch, onboard device, or a card in a PCI slot |
2015-12-31
|
| 1533184.1 |
M10-ioc.ch.se - Internal error detected by an IOC in a CPU chip |
2015-12-31
|
| 1531943.1 |
M10-io.pciex.switch.fe - Fatal error within a PCIe switch chip |
2015-12-31
|
| 1531462.1 |
M10-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated |
2016-01-06
|
| 1531454.1 |
M10-memory.se - A serious error has been detected at a DIMM |
2016-07-22
|
| 1530597.1 |
M10-memory.mirror.fe.addr - Fatal error in a DIMM |
2015-12-31
|
| 1527530.1 |
M10-cpu.chip.se - Uncorrectable error detected by a SPARC64 X CPU chip |
2015-12-30
|
| 1527089.1 |
M10-io.pcie.device.fe - Fatal error detected on a card in a PCI slot or an onboard device |
2015-12-31
|
| 1527087.1 |
M10-ioc.ch.fe - Fatal error within an IOC which is related to an IO Channel |
2015-12-31
|
| 1527083.1 |
M10-ioc.fe - Fatal error within an IOC detected by an IOC within itself |
2017-04-26
|
| 1527082.1 |
M10-mac.ce - Persistent correctable errors (CEs) detected by the MAC sub-chip within itself |
2015-12-31
|
| 1527079.1 |
M10-mac.se - A serious error was detected by the MAC sub-chip within itself |
2015-12-31
|
| 1527047.1 |
M10-mac.bank.fe - Fatal error detected by the MAC chip within itself |
2015-12-31
|
| 1527045.1 |
M10-mac.fe - Fatal error detected by the MAC within itself |
2015-12-31
|
| 1526831.1 |
Fujitsu M10-1/M10-4/M10-4S CRU / FRU Replacement Methods |
2018-03-01
|
| 1526814.1 |
M10-memory.bank.err - DIMM errors detected by Power On Self Test (POST) |
2015-12-31
|
| 1526751.1 |
M10-memory.block.pce - The number of DIMM permanent correctable errors (PCEs) exceeds threshold |
2015-12-31
|
| 1526724.1 |
M10-memory.block.mirror.ue - A data compare error has been detected when memory is in mirror mode |
2015-12-31
|
| 1526710.1 |
M10-memory.block.ue - DIMM uncorrectable error detected |
2015-12-31
|
| 1526677.1 |
M10-memory.fe - Fatal error in a DIMM |
2015-12-31
|
| 1526647.1 |
M10-cpu.way.ce - Persistent correctable errors (CEs) detected by a SPARC64 X CPU chip |
2015-12-30
|
| 1526644.1 |
M10-cpu.core.ce-offlinereq - Too many correctable errors (CEs) within a CPU core, (such as 05018200), have occurred |
2015-12-30
|
| 1526633.1 |
M10-cpu.core.ce - Persistent correctable errors (CEs) detected by a SPARC64 X CPU chip |
2016-01-06
|
| 1526624.1 |
M10-cpu.ce - Persistent correctable errors (CEs) detected by a SPARC64 X CPU chip |
2015-12-30
|
| 1526593.1 |
M10-cpu.core.se-offlinereq - Too many CPU serious faults, such as 05012700, have occurred |
2015-12-30
|
| 1526352.1 |
M10-cpu.core.se - Uncorrectable error detected by a SPARC64 X CPU chip |
2015-12-30
|
| 1526350.1 |
M10-cpu.se-offlinereq - Too many CPU faults, such as 05012100, have occurred |
2015-12-30
|
| 1526341.1 |
M10-cpu.se-uncertain - Uncorrectable error detected by a SPARC64 X CPU chip |
2015-12-30
|
| 1526261.1 |
M10-cpu.core.strand.fe - Internal fatal error within a strand on a SPARC64 X CPU |
2015-12-30
|
| 1526222.1 |
M10-cpu.se - Uncorrectable error detected by a SPARC64 X CPU chip |
2016-06-22
|
| 1524723.1 |
M10-cpu.core.fe - Internal fatal error within a core on a SPARC64 X CPU chip |
2015-12-30
|
| 1524707.1 |
M10-cpu.fe - Internal fatal error within a SPARC64 X CPU chip core |
2017-11-20
|
| 1523796.1 |
SCF-8008-V0 - Correctable errors on the interface between XB chip and CPU chip exceed an acceptable threshold. |
2017-03-23
|
| 1523795.1 |
SCF-8008-UT - Correctable errors on the interface between two CPU chips exceed an acceptable threshold |
2017-03-23
|
| 1523787.1 |
SCF-8008-Q1 - The number of permanent correctable errors (PCEs) on single DIMM exceeds an acceptable threshold |
2017-03-23
|
| 1523786.1 |
SCF-8008-PW - The number of intermittent correctable memory errors (ICEs) has exceeded an acceptable threshold |
2017-03-23
|
| 1523771.1 |
SCF-8008-WV - A non-fatal uncorrectable error was detected within a MBC chip |
2017-03-23
|
| 1523770.1 |
SCF-8008-T6 - Correctable errors on the interface between two XB chips exceed an acceptable threshold |
2017-03-23
|
| 1523769.1 |
SCF-8008-SN - A data compare error has been detected within a CPU MAC when memory is in mirror mode |
2017-03-23
|
| 1523767.1 |
SCF-8008-R9 - The number of intermittent correctable errors (ICEs) on single DIMM exceeds an acceptable threshold |
2017-03-23
|
| 1523747.1 |
SCF-8008-NF - A permanent correctable memory error (PCE) has been detected |
2017-03-23
|
| 1523673.1 |
SCF-8008-MK - An uncorrectable memory error (UE) has been detected |
2017-03-23
|
| 1523672.1 |
SCF-8008-L8 - A non-fatal uncorrectable error has been detected on a strand on a CPU chip |
2017-03-23
|
| 1523671.1 |
SCF-8008-KM - The number of correctable errors on a strand on a CPU chip has exceeded an acceptable threshold |
2017-03-23
|
| 1523646.1 |
SCF-8008-J7 - The number of correctable errors within a way of a CPU chip's cache has exceeded an acceptable threshold. |
2017-03-23
|