Solution Type  Predictive Self-Healing Sure

Solution  1531462.1 :   M10-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10-4S
SPARC

Purpose

Provide additional information for message ID: M10-device.misconfig_cmu_dimm

Fujitsu fault code:

018AF070

Details

Type

Hardware Fault
   device.misconfig_cmu_dimm

Severity

Major

Description

An error occurred during powerup when a memory configuration rule has been violated.

Automated Response

No immediate action is taken.

Impact

DIMM(s) will be deconfigured that have violated memory configuration rules.

Indicted Hardware

The affected DIMM(s) is/are marked for replacement. However, experience on previous M-Series platforms indicates that, once correctly configured, the DIMMs in question will function normally.

The clearstatus command should be run from XSCF to clear the fault status of the affected DIMM(s).

Suggested Action for System Administrator

Refer to the memory configuration rules outlined in the relevant SPARC M10 Service Manual for your system.