Asset ID: |
1-79-1531462.1 |
Update Date: | 2016-01-06 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1531462.1
:
M10-device.misconfig_cmu_dimm - An error occurred during powerup when a memory configuration rule has been violated
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10-4S
SPARC
Purpose
Provide additional information for message ID: M10-device.misconfig_cmu_dimm
Fujitsu fault code:
018AF070
Details
Type
- Hardware Fault
- device.misconfig_cmu_dimm
Severity
- Major
Description
-
An error occurred during powerup when a memory configuration rule has been violated.
Automated Response
- No immediate action is taken.
Impact
-
DIMM(s) will be deconfigured that have violated memory configuration rules.
Indicted Hardware
- The affected DIMM(s) is/are marked for replacement. However, experience on previous M-Series platforms indicates that, once correctly configured, the DIMMs in question will function normally.
The clearstatus command should be run from XSCF to clear the fault status of the affected DIMM(s).
Suggested Action for System Administrator
- Refer to the memory configuration rules outlined in the relevant SPARC M10 Service Manual for your system.

Attachments