| Asset ID: |
1-79-1570038.1 |
| Update Date: | 2016-01-04 |
| Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1570038.1
:
M10-upset.config.xbbox - A problem occurred during powerup
| Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
SPARC
Purpose
Provide additional information for message ID: M10-upset.config.xbbox
Fujitsu fault code:
018A0012
Details
Type
- Hardware Fault
- upset.config.xbbox
Severity
- Major
Description
-
A problem with XB-Box numbering was detected during powerup. Some XB-Boxes are missing or the system has two XB-Boxes but their BB-ID’s are not 80 and 81 e.g. they are set to 80 and 82 on a two XB-Box system.
Automated Response
- The powerup does not take place.
Impact
- Nothing is deconfigured.
Indicted Hardware
- The XB-Boxes are not faulty, just misconfigured.
Suggested Action for System Administrator
- Configure the XB-Box ids in accordance with instructions in the SPARC M10 Systems Installation Guide at docs.oracle.com.

Attachments
This solution has no attachment