Solution Type  Predictive Self-Healing Sure

Solution  1537510.1 :   M10-i2c.device_pcibox_fanbp - I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-i2c.device_pcibox_fanbp

Fujitsu fault code:

11000035

Details

Type

Hardware Fault
   i2c.device_pcibox_fanbp

Severity

Major

Description

Fault due to I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box.

These devices can no longer be accessed or controlled by the PCI expansion box firmware.

Automated Response

All the fans on the box are turned to high speed.

Impact

Nothing is deconfigured.

Indicted Hardware

The fan backplane FRU FANBP is marked for replacement.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)