It is possible to create a test fault and SNMP trap from the XSCF command line or BUI to check functionality of the M10 system fault reporting mechanism:
XSCF> rastest -c test
This will generate an error message that can be viewed with the showlogs error XSCF command, and, if SNMP is enabled on the XSCF, a test trap will be forwarded to any designated traphost(s).
XSCF> showlogs error
Date: Jul 10 09:21:25 PDT 2013
Code: 80000000-003e01009301009600-ff0200010000000000000000
Status: Alarm Occurred: Jul 10 09:21:21.666 PDT 2013
FRU: /BB#0/CMUL,/BB#0/OPNL,/BB#0/PSU#0
Msg: Pseudo error for test trap notice
The test trap will look something like this, for SNMP v2c:
2013-07-10 12:21:30 servername.customer.com [192.168.0.1]:
iso.3.6.1.2.1.1.3.0 = Timeticks: (131190664) 15 days, 4:25:06.64
iso.3.6.1.6.3.1.1.4.1.0 = OID:
iso.3.6.1.4.1.211.1.15.4.1.2.0.1
iso.3.6.1.4.1.211.1.15.4.1.1.12.2.1.13.1.0.2.0.254.0 = INTEGER: 3
iso.3.6.1.4.1.211.1.15.4.1.2.1.2.0 = INTEGER: 1
iso.3.6.1.4.1.211.1.15.4.1.1.4.3.0 = STRING: "2081234005"
iso.3.6.1.4.1.211.1.15.4.1.1.4.2.0 = STRING: "SPARC M10-4S"
iso.3.6.1.4.1.211.1.15.4.1.1.4.1.0 = STRING: "servername"
iso.3.6.1.4.1.211.1.15.4.1.2.1.14.0 = STRING: "FF020001"
iso.3.6.1.4.1.211.1.15.4.1.2.1.15.0 = STRING: "Jul 10 09:21:21.666 PDT 2013"
iso.3.6.1.4.1.211.1.15.4.1.2.1.16.0 = STRING: "https://support.oracle.com/msg/M10-Testalert
iso.3.6.1.4.1.211.1.15.4.1.2.1.17.0 = STRING: "PP123205RP "
iso.3.6.1.4.1.211.1.15.4.1.2.1.18.0 = STRING: "CA07361-D941 B0 /BGA-16CL-02 "
iso.3.6.1.4.1.211.1.15.4.1.2.1.19.0 = STRING: "PP123204ZG "
iso.3.6.1.4.1.211.1.15.4.1.2.1.20.0 = STRING: "CA07361-D012 A1 "
iso.3.6.1.4.1.211.1.15.4.1.2.1.21.0 = STRING: "MD12250534 "
iso.3.6.1.4.1.211.1.15.4.1.2.1.22.0 = STRING: "CA01022-0761 / "
iso.3.6.1.4.1.211.1.15.4.1.2.1.23.0 = STRING: "/BB#0/CMUL,/BB#0/OPNL,/BB#0/PSU#0"
iso.3.6.1.4.1.211.1.15.4.1.2.1.24.0 = STRING: "Fujitsu M10-4S"
iso.3.6.1.4.1.211.1.15.4.1.2.1.25.0 = INTEGER: 1
iso.3.6.1.4.1.211.1.15.4.1.2.1.26.0 = STRING: "M10-Testalert"