Asset ID: |
1-79-1537474.1 |
Update Date: | 2015-12-31 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1537474.1
:
M10-madm.io.se - MADM software running on the domain has detected a serious IO problem
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
Fujitsu M10-4
Fujitsu M10-1
SPARC
Purpose
Provide additional information for message ID: M10-madm.io.se
Fujitsu fault codes:
09010101, 09010102, 09010103, 09010104, 09010201, 09010202,
09010F01
Details
Type
- Hardware Fault
- madm.io.se
Severity
- Major
Description
-
Machine Administration software (MADM) running on the domain has detected a serious IO problem.
Exactly how serious the IO problem is can be found by running the showlogs CLI on the XSCF and looking at the madm-related log.
If the IO problem is related to a specific PCI card, the PCI card is identified. If the IO problem is not related to a PCI card, then the problem is due to a built-in GbE controller, a built-in USB controller, or built-in hard disk drives - however, the precise device that caused the problem is not identified on the XSCF.
Automated Response
- No immediate action is taken. The platform administrator should use the output of the showlogs command to determine if a service action is necessary.
Impact
- Nothing is deconfigured.
Indicted Hardware
- If the IO problem is related to a PCI card, then the PCI card is the only suspect.
If the IO problem is related to a built-in IO device, the entire chassis is put on the suspect list. Any suspects are not marked for replacement, since any marking of resources as faulty is performed on the domain.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)

Attachments
This solution has no attachment