Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1537488.1
Update Date:2015-12-31
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1537488.1 :   M10-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Fujitsu M10-4S
Fujitsu M10-1
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC

Purpose

Provide additional information for message ID: M10-io.pciex.pcibox.se

Fujitsu fault code:

11000041

Details

Type

Hardware Fault
   io.pciex.pcibox.se

Severity

Major

Description

Fault due to serious internal error detected by a link card or link board in a PCI expansion box.

The fault affects the PCI express fabric. The domain will face performance deterioration. The detected fault is listed in the following
categories:

- se-linkcard-lane-degraded: 11000041 The link card detects the PCIe lane has been degraded and is operating at reduced speed;

Automated Response

No immediate action is taken.

Impact

Nothing is deconfigured.

Indicted Hardware

First suspect is the link card, second suspect is a link cable between the link card and the PCI expansion box and the third suspect is the link board on PCI expansion box.

Suggested Action for System Administrator

The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)