Asset ID: |
1-79-1537469.1 |
Update Date: | 2015-12-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1537469.1
:
M10-domain.fe-unexpected-trap - An unexpected trap with unknown cause was detected by a CPU chip on a PPAR
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-1
Fujitsu M10-4S
Fujitsu M10-4
Fujitsu M10 PCI Expansion Unit
SPARC
Purpose
Provide additional information for message ID: M10-domain.fe-unexpected-trap
Fujitsu fault code:
02008000
Details
Type
- Hardware Fault
- domain.fe-unexpected-trap
Severity
- Major
Description
-
Fault due to an unexpected trap with unknown cause was detected by a CPU chip on a PPAR.
This fault is detected by POST. POST indicts a suspect depending on which POST test encountered the unexpected trap.
Automated Response
- The PPAR is reset.
Impact
- CPU core(s), a MAC sub-chip, an IOC sub-chip, DIMM(s), a building block, or a PCI expansion box is deconfigured.
Indicted Hardware
- Either the Motherboard (CMU or MBU), a DIMM, a PCIe card, or an IOB on a PCI expansion box is specified.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)