M10-env.temp.over-fail - Overtemperature fault
Related Items |
- Fujitsu M10-4
- Fujitsu M10-1
- Fujitsu M10 PCI Expansion Unit
- Fujitsu M10-4S
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
Fujitsu M10 PCI Expansion Unit
Fujitsu M10-4
Fujitsu M10-1
SPARC
Purpose
Provide additional information for message ID: M10-env.temp.over-fail
Fujitsu fault codes:
01910812, 01910912, 01910A12, 01910B12, 01910C12, 01910D12,
01910E11, 11000039
Details
Type
- Hardware Fault
- env.temp.over-fail
Severity
- Major
Description
-
Fault due to an overtemperature condition detected by a temperature sensor. This condition indicates a higher temperature than the overtemperature warning condition event described in:
M10-env.temp.over-warn - An overtemperature warning condition is detected by a temperature sensor (Doc ID 1535238.1)
There is risk of damage to hardware with this overtemperature condition.
The overtemperature condition was detected by:
- An inlet temperature sensor
- An exhaust temperature sensor
- A temperature sensor located on or near a:
- CPU
- DIMM
- XB chip
- PCI express switch chip
- SAS chip
- PSU
- DDC
The sensor could also be located on an XB-Box or PCI Expansion Unit.
Automated Response
- The platform administrator should investigate the cause of the overtemperature failure condition.
When this failure is detected in M10-1 or M10-4 servers, the platform is powered down.- When the fault is detected on a PSU, the PSU will be requested to power-off. And, the chassis will keep running with using remaining PSU, unless the other PSU is already faulted.
When this failure is detected in M10-4S servers, a PPAR which is using this building block is powered down.
When this fault is detected on a XB chip, PPARs using this XB-chip are powered down.
When this fault is detected in a PCI Expansion Unit, then this PCI Expansion Unit is powered down. Domains using this PCI Expansion Unit may lose communication on the PCI Express fabric and possibly panic.
Impact
- Nothing is deconfigured. If the platform is powered up while the temperature is still in the overtemperature range, another fault of this category will occur.
Indicted Hardware
- The suspect is the external environment.
Suggested Action for System Administrator
- Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)