M10-xb.fe - Fatal internal error detected by an XB chip within itself
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Fujitsu M10-4S
SPARC
Purpose
Provide additional information for message ID: M10-xb.fe
Fujitsu fault codes:
05066105, 05066106, 05066114, 05066117, 05066119, 0506611a,
0506611b, 0506611c, 0506611d, 0506611f, 05066124, 05066125, 05066126, 05066127,
05066128
Details
Type
- Hardware Fault
- xb.fe
Severity
- Major
Description
-
Fault due to a fatal internal error detected by an XB chip within itself.
Automated Response
- PPARs using this XB chip is reset.
Impact
- An XB-way is deconfigured on these PPARs.
Indicted Hardware
- XBU, where this XB chip is mounted, is marked for replacement.
Suggested Action for System Administrator
- The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the hardware may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Fujitsu M10 Diagnosis (Doc ID 1525156.1)