Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1526831.1
Update Date:2018-03-01
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1526831.1 :   Fujitsu M10-1/M10-4/M10-4S CRU / FRU Replacement Methods  


Related Items
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-4
  •  
  • Fujitsu M10-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




In this Document
Purpose
Scope
Details
 Maintenance Type Definitions:
 Active/hot maintenance
 Active/cold maintenance
 Inactive/hot maintenance
 Inactive/cold maintenance
 System-stopped maintenance
 M10-1
 M10-4
 M10-4S
 Crossbar Box
 Cables and Dedicated PDU


Applies to:

Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases]
Sun SPARC Sun OS

Purpose

This document describes the three replacement methods and provides information on which FRUs and CRUs can be replaced using which method(s).  This document should be used to decide which method is best to utilize given the system configuration and the FRU which requires service.

Scope

 

Details

Maintenance Type Definitions:

Active/hot maintenance

Maintenance work is performed while the physical partition remains turned on and the input power of the cabinet on which the target Field Replaceable Unit (FRU) is mounted is on (power cord is connected). Active/hot maintenance can be performed only on FRUs that have the redundant configuration or can use the PCI Hotplug (PHP) function.

Active/cold maintenance

Maintenance work is performed while the physical partition to which the maintenance-target FRU belongs remains turned on and the input power of the cabinet on which the target FRU is mounted is off (power cord is disconnected).

Note: Active/cold maintenance cannot be performed for single cabinet configuration.

Inactive/hot maintenance

Maintenance work is performed while the physical partition to which the maintenance-target FRU belongs is powered off and the input power of the cabinet on which the target FRU is mounted is on (power cord is connected).

Inactive/cold maintenance

Maintenance work is performed while the physical partition to which the maintenance-target FRU belongs is powered off and the input power of the cabinet on which the target FRU is mounted is off (power cord is disconnected

System-stopped maintenance

Maintenance work is performed while all the physical partitions are powered off and input power of the cabinet on which the target FRU is mounted is off (power cord is disconnected).

 

M10-1

FRU Active / Hot Inactive / Cold (System Stopped) CRU / FRU
Motherboard Unavailable Available FRU
Memory Unavailable Available FRU
Power Supply ( PSU ) Available Available FRU
Fan Unit Available Available FRU
Internal Disk Available (1) Available CRU
PCI Card Unavailable Available CRU
PSU Backplane Unavailable Available FRU
HDD Backplane Unavailable Available FRU
Operation Panel Unavailable Available FRU

 

1. Available only on an internal disk of devices other than boot device. However, if the boot device is in redundant configuration (RAID configuration), the active/hot maintenance is available.

 

M10-4

FRU Active / Hot Active / Cold Inactive / Hot Inactive / Cold System Stopped CRU / FRU
CPU Memory Unit Unavailable Unavailable Unavailable Unavailable Available FRU
Memory Unavailable Unavailable Unavailable Unavailable Available FRU
Power Supply ( PSU ) Available Unavailable Available Available Available FRU
Fan Unit Available Unavailable Available Available Available FRU
Internal Disk Available (1) Unavailable Available Available Available CRU
PCI Card Available Unavailable Unavailable Available Available CRU
PSU Backplane Unavailable Unavailable Unavailable Available Available FRU
Operation Panel Unavailable Unavailable Unavailable Available Available FRU

 

1. Available only on an internal disk of devices other than boot device. However, if the boot device is in redundant configuration (RAID configuration), the active/hot maintenance is available.

 

M10-4S

FRU Active / Hot Active / Cold Inactive / Hot Inactive / Cold System Stopped CRU / FRU
CPU Memory Unit Unavailable Unavailable Unavailable Unavailable Available FRU
Memory Unavailable Unavailable Unavailable Unavailable Available FRU
Power Supply ( PSU ) Available (1) Unavailable Available Available Available FRU
Fan Unit Available Unavailable Available Available Available FRU
Internal Disk Available (2) Unavailable Available Available Available CRU
PCI Card Available Unavailable Unavailable Available Available CRU
PSU Backplane Unavailable Unavailable Unavailable Available Available FRU
Operation Panel Unavailable Unavailable Unavailable Available Available FRU
Crossbar Unit Unavailable Unavailable Unavailable Available Available FRU

 

1: Active/hot replacement can be performed only with redundant configuration.
2: Available only on an internal disk of devices other than boot device. However, if the boot device is in redundant configuration (RAID configuration), the active/hot maintenance is available.

Crossbar Box

FRU Active / Hot Active / Cold Inactive / Hot Inactive / Cold System Stopped CRU / FRU
Crossbar Unit Unavailable Unavailable (1) Unavailable Unavailable (1) Available (2) FRU
XSCF Unit Available (3) Unavailable (1) Available Unavailable (1) Available (2) FRU
Power Supply ( PSU ) Available (4) Unavailable (1) Available Unavailable (1) Available (2) FRU
Fan Unit Available Unavailable (1) Available Unavailable (1) Available (2) FRU
Crossbar Backplane Unavailable Unavailable (1) Unavailable Unavailable (1) Available (2) FRU
Fan Backplane Unavailable Unavailable (1) Unavailable Unavailable (1) Available (2) FRU
Operation Panel Unavailable Unavailable (1) Unavailable Unavailable (1) Available (2) FRU

 

1: If there is any physical partition in operation, the crossbar box cannot be powered off.
2: All physical partitions must be powered off, and the system must be completely shut down.
3: It is necessary that the XSCF has become a slave before maintenance work is started. If it is operating as the master XSCF, switch it to the standby XSCF.
4: Active/hot replacement can be performed only with redundant configuration.

Cables and Dedicated PDU

FRU Active / Hot Active / Cold Inactive / Hot Inactive / Cold System Stopped CRU / FRU
Crossbar Cable ( elect. ) Unavailable Unavailable Available Available Available CRU
Crossbar Cable ( optical ) Unavailable Unavailable Available Available Available FRU
XSCF BB control cable Available (*) Available Available Available Available FRU
XSCF DUAL control cable Available (*) Available Available Available Available FRU
Dedicated PDU Unavailable Available Unavailable Unavailable Available FRU

 

*: It is necessary that the XSCF become a slave before maintenance work is started. If it is operating as the master XSCF, switch it to the standby XSCF


Attachments
This solution has no attachment